XN-9100 Workload Balance

  • Flexible rack entry and exit positions, also as single point of entry/exit
  • Expand the initial configuration at any stage
  • Discrete rack management
  • Built-in auto reflex

XN-9100 - tube sorter becomes the sample manager

  • The XN-9100 Workload Balance configuration is an advanced work area automation concept best suited to labs with a varied sample profile and a need for pre-sorting. By pre-sorting the tubes to user-defined criteria, you optimise processing capacity and sample distribution across the analysis units.
  • With pre-sorting, sorting and archiving, this configuration helps optimise sample collection and fast distribution to other work areas. You can add variable clinical and productivity values, an optional slide-maker/stainer or digital imaging module.
  • This configuration is especially easy to operate as it has just a single point of entry. Tubes are placed at the entry point and fed into the tube sorter (TS-10) and registered. They are then grouped by measurement profile, patient information or any other sorting priorities you care to define. Tubes are processed as batch and transported per rack via the belt system to the XN units.
  • Negative results are validated automatically by the rule set, which contributes to reduced TAT and increased efficiency of the lab staff. Once the order processing is complete, the tubes are archived automatically. If there are still outstanding analysis orders, they are sorted for subsequent work areas.
  • Alternative designs can be installed to make best use of your space, or when the available space is not enough for a linear set-up: Inner-L, Outer-L, Inner-U, Outer-U, Z

 

 

Extended IPU

Extended IPU

The Extended IPU, as an integrated component of all XN-9100 configurations, controls the complete order management for the EDTA tubes. With rack management and tube registration each individual EDTA tube is fully traceable.

Specifications

Specifications

Measurement principles

WBC DIFF/RET/PLT-F/WPC: Fluorescence flow cytometry
RBC/PLT: Hydrodynamically focussed impedance
HGB: Cyanide-free SLS haemoglobin

Aspiration volume    

XN module: 88 µL in whole blood (WB) mode and body fluid (BF) mode
SP-50 module: 70 µL for smear preparation in auto mode,
38 µL for smear preparation in manual mode

Throughput    

From two XN-10/20 modules in combination with SP-50 (H mode): from 200 samples/h in whole blood (WB) mode, up to 40 samples/h in body fluid (BF) mode per module, up to 75 slides/h per module

Quality control    

XN Check (three levels) and XN Check BF (two levels)

Parameters    

XN-CBC = always with NRBC

Whole Blood

WBC, NRBC%, NRBC#, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MicroR%, MacroR%, PDW, MPV, P-LCR, PCT, NEUT%, NEUT#, LYMPH%, LYMPH#, MONO%, MONO#, EO%, EO#, BASO%, BASO#, IG%, IG#

With RET (optional)   

RET%, RET#, IRF, LFR, MFR, HFR, RET-He, RBC-He, Delta-He, HYPO-He%, HYPER-He%, PLT-O

With PLT-F (optional)       

PLT-F, IPF, IPF#

With WPC (optional)   

Extended Inflammation Parameters licence: NEUT-GI, NEUT-RI, RE-LYMP%, RE-LYMP#, AS-LYMP%, AS-LYMP#

XN Stem Cells licence        

HPC%, HPC#

Body Fluids with XN-BF   

WBC-BF, RBC-BF, MN%, MN#, PMN%, PMN#, TC-BF#
(optional)

Integrated optional modules

DI-60 for digital image analysis
Tube sorter TS-10
Tosoh HLC-723 G11* – automated glycohaemoglobin analyser

* only in certain countries

Configurations

XN-9100 WB [DIFF]
XN-9100 WB [WPC]