HISCL™ ADAMTS13 Activity Assay Kit

ADAMTS13 Activity testing with HISCL CLEIA technology

The measurement of ADAMTS13 Activity, alongside clinical pre-probability scores and clinical presentation, is crucial in the diagnosis of Thrombotic Thrombocytopenic Purpura (TTP). The new HISCL ADMATS13 Activity Assay Kit provides a highly sensitive and specific CLEIA assay to aid the diagnosis of TTP utilising the internationally recognised 10 IU/dL cut-off1. 

Features

Thrombotic Thrombocytopenic Purpura (TTP) 

ADAMTS13 is an enzyme that regulates blood clot formation by cleaving ultra-large von Willebrand factor (vWF) multimers, preventing excessive platelet aggregation. Severe ADAMTS13 deficiency (congenital or immune mediated) can lead to thrombotic thrombocytopenic purpura (TTP), a rare, life-threatening blood disorder characterised by platelet-rich microvascular thrombi, thrombocytopenia and haemolytic anaemia. Early diagnosis and prompt treatment are critical, as untreated TTP has a mortality rate exceeding 90%, whereas modern therapies have significantly improved patient survival. 

Reference:

Kubo M, Konko K, Kinoshita E, Uemae S, Kobayashi K, Hayashi Y, Kan A, Fujimura Y, and Matsumoto M. A novel automated chemiluminescent enzyme immunoassay for ADAMTS-13 activity enables accompanying measurements of the inhibitory autoantibodies. J Thromb Haemost. 2025 Mar; 23(3): 957–967.

 

 

HISCL ADAMT13 Assay Principle – powered by CLEIA 

This kit quantifies ADAMTS13 activity in the sample based on a 2-step CLEIA principle. 

  1. The biotinylated-vWF73 peptide in the R1 reagent is cleaved by the ADAMTS13 in the sample. The cleaved portion of the biotinylated-vWF73 peptide is captured by the streptavidin-coated magnetic particles (MP) in the R2 reagent. 
  2. After B/F (Bound and Free) separation, alkaline phosphatase (ALP)-conjugated anti-cleaved vWF73 peptide antibody (anti-N10) in the R3 reagent bind to the cleaved biotinylated-vWF73 peptide on the MP.
  3. After B/F separation, the ALP-conjugated antibody on the MP reacts with CDP-Star™ substrate in the R5 reagent to produces a luminescent signal.
  4. The light emission is directly proportional to the ADAMTS13 activity. 

The signal from an unknown sample is compared to a calibration curve, created using a sample containing a known and traceable amount of ADAMTS13 activity (HISCL ADAMTS13 Calibrator) to generate a result in international units per decilitre (IU/dL). 

Technical Specifications
Measurement item
ADAMTS13 Activity 
Packaging
50 tests/package
Measurement principle
Chemiluminescent enzyme immunoassay (CLEIA)
Purpose of use
An in vitro diagnostic reagent kit for the quantification of ADAMTS13 activity in human plasma
Sample type
Human citrated plasma
Measurement range
0.50 – 120.0 IU/Dl
Cut-off value
10 IU/dL
Time to result
20 minutes
On-board stability 60 days 
Applicable instruments
Sysmex Automated Blood Coagulation Analyser CN-3500/CN-6500

 

Contact
You have a question and would like to get in touch with our experts? We look forward to receiving your enquiry.

Sysmex UK LTD

Sysmex House

Garamonde Drive

Wymbush

Milton Keynes

MK8 8DF

0333 320 3460

Explore more

CA-660

CA-660

Complete profiles, robust and automated

Details
CN track

CN track

Coagulation transportation system

Details
CN-6000/CN-3000

CN-6000/CN-3000

Power in a new dimension

Details
Copyright © Sysmex Europe SE. All rights reserved.